Venting cooling system:

Note:

Do not open the coolant expansion tank cap during the venting
procedure.

1. 

Connect battery charger.

2. 

Switch on ignition.

3. 

Set heater to maximum temperature and turn fan down to

lowest speed.

4. 

Press accelerator pedal for 10 seconds to floor.  Engine

must  not be started.

5. 

The venting procedure is started when the accelerator pedal

is pressed and takes approx. 12 minutes.(Electric coolant
pump was activated and shuts down automatically after
approx. 12 minutes).

6. 

Then top up fill level in coolant expansion tank with 100 ml

above max. (see Fig. R17 0450).

7. 

Check cooling system for leaks.

8. 

If venting has to be carried out again (e.g. if cooling system is

leaking), allow DME to fall completely (leave ignition key
removed for approx. 3 minutes), then repeat from Point 3.

Only when venting!

Perform filling operation slowly.

Fill coolant expansion tank with 100 ml above max.

100 ml corresponds to A=6 mm.

Close coolant expansion tank.

Installation:

Close cap (1) until the arrow marks line up.