bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

3 RA Replacing Control Module (DME) > < 1 RA Replacing Pulse Generator On Crankshaft (M43TU)
Page 1
background image

12 14 523

Replacing pulse generator on inlet camshaft
(M43TU)

Turn off ignition.

To facilitate work, unscrew solenoid valve (1) with retainer.

Disconnect plug connection (2).

Release screw on pulse generator.

Remove pulse generator (1).

Installation:

Check sealing ring for possible damage, replace if necessary.

Read out fault memory of DME control module, check stored fault
messages, rectify faults, cancel fault memory.

RA  Replacing pulse generator on inlet camshaft (M43TU)

BMW AG - TIS

19.01.2013  10:55

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

3 RA Replacing Control Module (DME) > < 1 RA Replacing Pulse Generator On Crankshaft (M43TU)