24 34 865

Replacing pressure regulator - oil sump
removed (A4S 270R/ 310R)

Press off wires (1 and 2).

Remove screw (3).

Important!

Inch threads.

Take off holder (4).

Pull out pressure regulator.

Installation:

Insert pressure regulator.

Install holder (4) with curved surface facing out and tighten bolt.

Tightening torque,

refer to Technical Data.