12 42 500

Replacing battery positive lead (between
jump-start connection point, alternator and
starter motor) (N42, N40, N46, N45, N43)

Necessary preliminary tasks:

Read out fault memory of DME control unit

Switch off ignition

Disconnect battery negative lead

Remove intake air manifold

E46:

Fold up protective cap (1).

Slacken nut (2).

Disconnect battery positive lead (3) from jump start terminal.

Tightening torque  12 42 1AZ

.

E81, E87, E90:

Take off cap.

Unfasten nut.

Disconnect battery positive lead (1) from jump start terminal.

Tightening torque  12 42 1AZ

.