13 62 601

Replacing pulse generator on left inlet
camshaft (S65)

(cylinder bank 5 to 8)

Necessary preliminary tasks:

Read out fault memory of DME control unit; if necessary,

work through test schedules

Switch off ignition

Remove intake filter housing

Remove left ignition coil cover

Release plug connector (1) and pull off.

Release screw.

Remove pulse generator (2).

Installation:

Replace sealing ring and coat with antiseize agent.

Tightening torque,  13 62 5AZ

Note:

Now clear the fault memory.

RA  Replacing pulse generator on left inlet camshaft (S65)

BMW AG - TIS

21.02.2013  19:46

Issue status (12/2007) Valid only until next DVD is issued