bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

6 RA Safety Rules For Working On Vehicles With Autogas Systems (CNG) > < 5 RA Opening_closing CNG-Swage-Lok Connection
Page 2
background image

Mark nut (1) and screw connection body (2) with paint. Brace
screw connection body (2) with open-end wrench and tighten
down nut (1) at 90

°

.

After assembly, perform a leak and pressure test,

refer to 13 80 600

If there are any leaks, retighten screw connection by no more than
45

°

.

If there is still a leak after this repeat leak and pressure test,
replace the pipe with clamping rings and the screw connection
body.

RA  Opening/closing CNG-Swage-Lok connection

BMW AG - TIS

15.01.2013  13:13

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

6 RA Safety Rules For Working On Vehicles With Autogas Systems (CNG) > < 5 RA Opening_closing CNG-Swage-Lok Connection