5 Series E34 518g (M43) TOUR
Connect special tool 13 8 010 to diagnosis connector, switch on
ignition and operate special tool to activate high-pressure non-
return valve.
Caution!
Always remove special tool 13 8 010 before test runs to
avoid malfunctions.
Connect special tool 16 8 010 to filler connection. Connect hose
to workshop compressed air circuit (dehumidified air).
Check all screw connections on high-pressure relief valve for
leaks with leak tester spray.
Check screw connection on front axle support for leaks with leak
tester spray.
RA Checking CNG system for leaks and correct pressure (E34)
BMW AG - TIS
15.01.2013 13:29
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 2 -