background image

Check screw connection (1/2/3) on high-pressure non-return valve
for leaks with leak tester spray.

Check screw connection (1) between gas bottle and high-pressure
non-return valve for leaks with leak tester spray.

Remove complete tank trim. Unfasten hose clip from hose sheath
and slide back hose sheath. Check connection between high-
pressure non-return valve and gas bottle for leaks with leak tester
spray.

Unfasten hose clip (1) and slide back hose sheath.