64 50 009

Drawing off, evacuating and filling A/C system
(R 134a)

Warning!

Refrigerant circuit is under high pressure!

Repair work may only be carried out on a DEPRESSURIZED
refrigerant circuit!

Avoid contact with refrigerant and refrigerant oil.

Follow safety instructions for handling refrigerant R 134a .

Follow safety instructions for handling refrigerant oil.

Important!

Risk of damage!

Only BMW-approved R134a refrigerant may be used (refer to
sourcing reference: Operating Fluids).

Restart engine only when A/C system has been correctly
filled.

Note:

Draw off, evacuate and fill the A/C system in accordance with the
operating instructions of the relevant service station.

E60 only:

If necessary, to connect service station, use manufacturer's
adapter for high-pressure connection (red).

Instructions for drawing off A/C system:

To help separation of refrigerant and refrigerant oil, run engine at
low speed (800-1200 rpm) and with A/C system turned on for a
few minutes.

The limits the entrainment of refrigerant oil while it is drawn off.

Drawn-off refrigerant oil must be changed and reintroduced via the
service station.

RA  Drawing off, evacuating and filling A/C system (R 134a)

BMW AG - TIS

23.01.2013  08:19

Issue status (12/2007) Valid only until next DVD is issued