10 RA Instructions For Opening And Replacing Parts In Refrigerant Circuit > < 9 RA Drawing Off, Evacuating And Filling A_C System (R 134a)
Page 2
background image

If at the end of the drawing-off procedure the service station
moisture indicator shows that the drawn-off refrigerant is
excessively moist, clean the refrigerant in accordance with the
service station operating instructions.

Recycling:

Dispose of drawn-off refrigerant oil as hazardous waste. 

Observe country-specific waste-disposal regulations.

Instructions for evacuating off A/C system:

The evacuation procedure removes all traces of ambient air, water
vapour and any other gases present from the A/C system. This
enables subsequent system filling with refrigerant.

A decrease in the vacuum level indicates a leak in the refrigerant
circuit.

Instructions for filling A/C system:

Before filling with refrigerant, top up the refrigerant oil entrained
during drawing off.

Follow instructions for opening and replacing parts in refrigerant
circuit!

Depending on the type of component replaced on the A/C system,
it may be necessary to top up the refrigerant oil, even if no
measurable losses have occurred during drawing off. Read and
comply with the A/C system manufacturer's notes in this regard
and the operating instructions of the relevant service station.

Information on the required refrigerant fill quantity for the entire
A/C system is contained on the rating plate (1) in the engine
compartment.

If necessary, refer to Technical Data for fill quantities.

Installation:

Reseal refrigerant filler necks on vehicle with sealing caps.

RA  Drawing off, evacuating and filling A/C system (R 134a)

BMW AG - TIS

23.01.2013  08:19

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

10 RA Instructions For Opening And Replacing Parts In Refrigerant Circuit > < 9 RA Drawing Off, Evacuating And Filling A_C System (R 134a)