bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

7 RA Fault 07 Overheating Protection > < 5 RA Fault 05 Temperature Sensor
Page 1
background image

64 99 ...

Fault 06 Park heating metering pump

Test precondition:

Overheating protection not active. Voltage supply at independent parking heater O.K.

Coolant temperature < 40 

0

 C

Vehicle tank adequately filled.

Instruction:

Switch on independent parking heater via MID or on-board monitor.

Check clock pulse at metering pump 32 seconds after switching on independent parking heater.

Question

Measure

Can clock pulse be heard at
metering pump?

No

Fault 6.1

Yes

Disconnect fuel hose at independent
parking heater and start independent
heater several times if necessary
until fuel emerges at heater
connection.
To measure delivery capacity, start
independent parking heater twice
and measure fuel quantity for 60
seconds at a time. Project metering
quantity for 1 hour. 
Is a metering quantity of 650 ml/h 

±

10

%

 reached?

No

Fault 6.2

Yes

The metering pump is O.K.

RA  Fault 06 Park heating metering pump

BMW AG - TIS

22.02.2013  04:47

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

7 RA Fault 07 Overheating Protection > < 5 RA Fault 05 Temperature Sensor