bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

5 RA Replacing Pulse Generator On Left Inlet Camshaft (N62, N62TU)|Page 831 > < 4 RA Replacing Crankshaft Pulse Generator (N62, N62TU)
Page 1
background image

12 14 522

Replacing pulse generator on left inlet
camshaft (N62, N62TU)

(cylinder bank 5 to 8)

Necessary preliminary tasks:

Read out fault memory of DME control unit; if necessary,

work through test schedules

Switch off ignition

Remove acoustic cover

Remove left ignition coil cover

Release plug connector (1) and pull off.

Release screw.

Remove pulse generator (2).

Installation:

Replace sealing ring and coat with antiseize agent.

RA  Replacing pulse generator on left inlet camshaft (N62, N62TU)

BMW AG - TIS

08.02.2013  04:00

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

5 RA Replacing Pulse Generator On Left Inlet Camshaft (N62, N62TU)|Page 831 > < 4 RA Replacing Crankshaft Pulse Generator (N62, N62TU)