Screw cap (1) onto special tool  17 0 007 .

Pressure relief valve must open between 1.65 and 2.2 bar.

Build up pressure with special tool  17 0 002  and watch
pressure gauge to ascertain when opening pressure is reached.
Note down measured opening pressure.

After a waiting period of approx. 30 seconds, the pressure must
no longer drop by more than 0.4 bar below the measured
opening pressure.

RA  Checking cooling system for leaks (N62)

BMW AG - TIS

16.02.2013  03:01

Issue status (12/2007) Valid only until next DVD is issued