bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

2 RA Replacing Air Supply Unit (two-axle Ride-height Control) > < 1 RA Replacing Air Supply Unit (ride-height Control)
Page 2
background image

Important!

Risk of damage!

Do not kink, twist or crush pipes.

Release screw (1).

Expose wiring harness with pipes up to air supply unit.

Unfasten screws (2).

Remove air supply unit (3) with wiring harness and pipes.

After installation:

Activating and filling air spring system:

Insert fuse in corresponding slot in fuse box

Connect BMW diagnosis system

Switch ignition on.

Fill rear left or right air spring using the BMW diagnosis

system (control unit functions -> component activation:
activate menu items "Fill rear left/right air spring" once)

Check pressure at the air springs.

Note: If an air spring feels soft, carry out troubleshooting
on the air supply unit.

Set vehicle down on its wheels

RA  Replacing air supply unit (ride-height control)

BMW AG - TIS

12.02.2013  09:21

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

2 RA Replacing Air Supply Unit (two-axle Ride-height Control) > < 1 RA Replacing Air Supply Unit (ride-height Control)