X Series E70 X5 4.8i (N62TU) OFFRD
Press sealing cap (1) inwards and remove circlip (2).
With assistance of a screwed-in screw (1), remove sealing
cap from condenser (3).
Installation:
Replace sealing rings (1) of sealing cap (2) and coat with
refrigerant oil.
Important!
Risk of damage!
Removal is made more difficult if rib (2) is damaged!
Carefully pull out desiccant insert (1) with a pair of wide pliers on
rib (2).
RA Replacing desiccant insert for A/C system
BMW AG - TIS
08.02.2013 15:43
Issue status (12/2007) Valid only until next DVD is issued
Copyright