Disconnect plug connection for lambda monitor sensor.

Release monitor sensor (1) with special tool  11 4 260 .

Tightening torque: 11 78 1AZ

.

Installation:

Cable colour black, cylinders 1 to 3.

Note:

To remove the monitor sensor for cylinders 4 to 6, it is
necessary to remove the exhaust system.

Disconnect plug connection for lambda monitor sensor.

Release monitor sensor (1) with special tool  11 4 260 .

Tightening torque: 11 78 1AZ

.

Installation:

Cable colour gray, cylinders 4 to 6.

Assemble engine.

Check function of DME.