Tighten the bolt to 20 N.m (15 lb ft).
13. Install the bolts to the upper support brackets of the HVAC module.
Tighten the bolts to 10 N.m (89 lb in).
14. Install the center support bracket to the HVAC module assembly.
15. Install the bolts to the center support bracket of the HVAC module assembly.
Tighten the bracket bolts to 10 N.m (89 lb in).
16. Install the instrument panel wiring harness on to the cross vehicle beam and secure the retaining clips.
17. Install the 2 screws below the fuse block that support the main wire harness connector to the cross vehicle beam.
18. Install the BCM bracket and the bolts.
Tighten the bolts to 10 N.m (89 lb in).
19. Install the relay bracket and the bolts.
Tighten the bolts to 10 N.m (89 lb in).