Electra V6-260 4.3L DSL (1984)
2.
Align offset tang on pump drive shaft with pump driven gear, Fig. 48.
3.
Install new pump to adapter O-ring, then install pump.
4.
If a new intermediate adapter is installed, set injection pump at center of slots in pump mounting flange. If original intermediate adapter is being
used, align pump timing mark with mark on intermediate adapter. Install two bolts and washers retaining pump and torque bolts to 35-37 ft. lbs.
5.
Reverse steps 1 through 8 of removal procedure for remainder of installation. If necessary adjust T.V. cable, pump timing, vacuum regulator valve
or idle speed.