procedures and short-cutting refrigerant recycling times. Use the following procedure for testing and correcting air contamination in your A/C service
equipment.

1.

Make certain that the ACR4 equipment has not been used for at least 12 hours. It is recommended that the equipment be left in an area where the
temperature will remain constant overnight to allow the temperature of the refrigerant in the tank to stabilize.

2.

Record the surrounding air temperature next to the ACR4 refrigerant tank.

Important

A major assumption is that the ambient air temperature next to the tank represents the refrigerant temperature in the tank. Failure to take care
in measuring the temperature could result in unnecessary work.

3.

Close both liquid (blue) and vapor (red) valves on the ACR4 tank.

4.

Disconnect low side (blue) service hose from the back of the ACR4.

5.

Slowly disconnect the tank vapor hose (red) from the back of the ACR4 and connect it to the low side service port.

6.

Open the vapor (red) valve on the tank and record the tank pressure on the low side gage.

7.

Restore hoses to the original position.

8.

Referring to the Table, find the ambient temperature measured in Step 2. Compare the pressure reading from Step 6 to the "maximum allowable
pressure". If the pressure reading from Step 6 is less than the "maximum allowable pressure", no further action is necessary.

Important

The closer the tank pressure is to the desired tank pressure, the better the A/C system will perform.

9.

If the pressure reading from Step 6 exceeds the maximum allowable pressure from the Table, open both tank valves and operate the ACR4 through
4 or 5 evacuation cycles. This will activate the automatic air purge to lower the tank pressure.

Important

Station should not be connected to vehicle.

10.

Repeat the tank pressure checking procedure the next day to determine if the pressure has been reduced to acceptable levels. If the tank pressure
has been reduced but is not acceptable, cycle with ACR4 through more evacuation cycles and recheck the next day. Continue process until
acceptable pressure is obtained. If the tank pressure is not reduced through the evacuation cycling, then Kent-Moore should be contacted at
1-800-345-2233.