Fuel Pressure Release: Service and Repair
Fuel System Pressure Relief

TOOLS REQUIRED

-

J 34730-1A Fuel Pressure Gage

-

J 42242 Fuel Pressure Gage Adapter

1. Turn the ignition OFF.

CAUTION:  
-

Refer to Gasoline/Gasoline Vapors Caution in Service Precautions.

-

Remove the fuel tank cap and relieve the fuel system pressure before servicing the fuel system in order to reduce the risk of personal
injury. After you relieve the fuel system pressure, a small amount of fuel may be released when servicing the fuel lines, the fuel injection
pump, or the connections. In order to reduce the risk of personal injury, cover the fuel system components with a shop towel before
disconnection. This will catch any fuel that may leak out. Place the towel in an approved container when the disconnection is complete
.

2. Disconnect the battery negative cable in order to avoid possible fuel discharge if an accidental attempt is made to start the engine.
3. Loosen the fuel filler cap to relieve the fuel tank vapor pressure.
4. Remove the cap on the fuel pressure service connection.

NOTE:  Clean all of the following areas before performing any disconnections in order to avoid possible contamination in the system:
-

The fuel pipe connections

-

The hose connections

-

The areas surrounding the connections

1. Connect the J 34730-1A (1) and the J 42242 (2) to the fuel pressure service connection. Wrap a shop towel around the fitting while connecting the

gauge to avoid spillage.

CAUTION:  Wrap a shop towel around the fuel pressure connection in order to reduce the risk of fire and personal injury. The towel will
absorb any fuel leakage that occurs during the connection of the fuel pressure gage. Place the towel in an approved container when the
connection of the fuel pressure gage is complete
.

2. Place the bleed hose of the J 34730-1A (1) into an approved gasoline container.

CAUTION:  Do not drain the fuel into an open container. Never store the fuel in an open container due to the possibility of a fire or an
explosion.

3. Open the bleed valve on the J 34730-1A (1) in order to bleed the fuel system pressure. The fuel connections are now safe for servicing.
4. Place a shop towel under the fuel pressure service connection to catch any remaining fuel spillage.
5. Remove both the J 34730-1A (1) and the J 42242 (2) from the fuel pressure service connection.
6. Drain any fuel remaining in the J 34730-1A (1) into an approved gasoline container.
7. Install the cap on the fuel pressure service connection.