Evaporator Temperature Sensor / Switch: Description and Operation

AIR TEMPERATURE

Evaporator Temperature Sensor
The HVAC control module monitors the temperature of the air passing through the evaporator by the A/C evaporator air temperature sensor. This
sensor is located on the evaporator core. The temperature is used to cycle the A/C compressor ON and OFF to prevent the evaporator core from
freezing. A thermistor inside the sensor varies its resistance to monitor the evaporator air temperature. The HVAC control module monitors the
voltage drop across the thermistor when supplied with a 5 volt reference signal. The HVAC control module will send a class 2 message to the ECM to
stop requesting the A/C compressor clutch operation if the temperature drops below 3°C (37°F). The sensor must be above 4°C (39°F) to request the
A/C compressor clutch again. The sensor operates within a temperature range between -40°C (-40°F) to 215°C (355°F). If the HVAC control module
detects an open in the evaporator temperature sensor or circuit, the class 2 message sent to the ECM will not submit the "A/C ON" request. The
HVAC control module will then send a request to the Radio for display of the "SERVICE A/C SYSTEM" that will be displayed on the DIC. The
HVAC control module will also display A/C OFF on the module as long as the condition is present.