TOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant.
2. Remove the air deflector.
3. Remove the bolt (2) that holds the compressor discharge hose to the compressor.
4. Separate the compressor discharge hose from the compressor.
5. Remove the bolt (1) from the condenser.
6. Disconnect the discharge line from the condenser.
7. Remove the discharge hose.
INSTALLATION PROCEDURE
1. Lubricate the O-rings.
2. Install the discharge hose.
3. Connect the discharge hose to compressor.