cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 1941 > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 1939
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENT

TOOLS REQUIRED

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Recover the refrigerant.

IMPORTANT:  There is no schrader valve under the pressure sensor.

2. Remove the air cleaner assembly.

3. Disconnect the electrical connector (1) from the A/C refrigerant pressure sensor (2).
4. Remove the A/C refrigerant pressure sensor.

INSTALLATION PROCEDURE

1. Lubricate the O-ring with refrigerant oil.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the A/C refrigerant pressure sensor (2).

Tighten
Tighten the sensor to 9.8 N.m (87 lb in).

3. Connect the electrical connector (1) to the A/C refrigerant pressure sensor.

Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 1941 > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 1939