cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 7948 > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 7946
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENT 

TOOLS REQUIRED 
J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE 

IMPORTANT:  No schrader valve appears under the pressure sensor.

1. Recover the refrigerant.
2. Remove the air cleaner assembly.

3. Disconnect the electrical connector (1) from the A/C refrigerant pressure sensor (2).
4. Remove the A/C refrigerant pressure sensor.

INSTALLATION PROCEDURE 

1. Lubricate the O-ring with refrigerant oil.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the A/C refrigerant pressure sensor (2).

Tighten 
Tighten the sensor to 9.8 N.m (87 lb in). 

3. Connect the electrical connector (1) to the A/C refrigerant pressure sensor.
4. Install the air cleaner assembly.
5. Evacuate and recharge the A/C system.

Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 7948 > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 7946