cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Disconnect/Connect Procedure|Page 9838 > < Jump Starting|Service Precautions|Page 9832
Page 1
background image

Negative: Service and Repair
Disconnect/Connect Procedure

BATTERY NEGATIVE CABLE DISCONNECT/CONNECT PROCEDURE

REMOVAL PROCEDURE

1. Turn off all the lamps and accessories.

CAUTION: Refer to Battery Disconnect Caution in Service Precautions.

2. Turn the ignition OFF.

3. Disconnect the battery negative cable (2) from the battery.

INSTALLATION PROCEDURE

1. Connect the battery negative (2) cable to the battery.

IMPORTANT:  Clean any existing corrosion from the battery terminal, the battery cable bolt and the battery cable.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the battery cable bolt to 17 N.m (13 lb  ft).

2. Power Windows calibration:

1. Repeat these steps for each window.
2. Turn the ignition switch to the RUN position.
3. Press the power window switch to the down position. After the window is in the full down position, press and hold the switch in the down

position for 3 seconds.

4. Press the power window switch to the up position. After the window is in the full up position, press and hold the switch in the up position for 3

seconds.

Disconnect/Connect Procedure|Page 9838 > < Jump Starting|Service Precautions|Page 9832