cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 (1500 Series)|Page 4636 > < Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 (1500 Series)|Page 4634
Page 11
background image

Caution:  Refer to Heated Oxygen and Oxygen Sensor Caution   (See: Service Precautions/Heated Oxygen and Oxygen Sensor Caution).

1. Remove the right wheelhouse liner. Refer to Front Wheelhouse Liner Replacement - Right Side   (See: Body and Frame/Fender/Front

Fender/Front Fender Liner/Service and Repair/Front Wheelhouse Liner Replacement - Right Side).

2. Remove the connector position assurance (CPA) retainer (2).
3. Disconnect the HO2S electrical connector (7) from the engine wiring harness electrical connector (1).
4. Remove the HO2S clip (8) from the engine wiring harness.

Caution:  Refer to Excessive Force and Oxygen Sensor Caution   (See: Service Precautions/Excessive Force and Oxygen Sensor Caution).

5. Remove the HO2S (3).

Installation Procedure

Note:  A special anti-seize compound is used on the HO2S threads. The compound consists of liquid graphite and glass beads. The graphite tends to
burn away, but the glass beads remain, making the sensor easier to remove. New, or service replacement sensors already have the compound applied to

Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 (1500 Series)|Page 4636 > < Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 (1500 Series)|Page 4634