Refrigerant: Service and Repair

If oil was removed from the A/C system during the recovery process or due to component replacement, the oil must be replenished. Oil can be injected
into a charged system using J 45037 For the proper quantities of oil to add to the A/C refrigerant system, refer to Refrigerant System Capacities.

Flushing
TOOLS REQUIRED
^

J 43600 Air Conditioning Service Center

^

J 45268 Flush Adapter Kit

^

J 41447 Leak Detection Dye

^

J 41459 Leak Detection Dye Injector

^

J 42220 Universal Leak Detection Lamp

IMPORTANT:  Flushing is not intended to remove metal from the A/C system.

Flushing is intended to remove the following:
^

Contaminated PAG oil

^

Desiccant, following a desiccant bag failure

^

Overcharge of PAG oil

^

Refrigerant contamination

IMPORTANT:  Warmer engine or ambient temperature decreases the refrigerant recovery time during the A/C flush procedure.

1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Remove the orifice tube.
3. Connect the A/C lines with the orifice tube removed.
4. Remove the A/C compressor.
5. Inspect the end of the suction hose for a suction screen.
6. Remove the suction screen, if installed.
7. Install the J 45268-4 to the A/C compressor suction hose.
8. install the J 45268-5 to the A/C compressor discharge hose.
9. Forward flow refrigerant flushing is recommended for contaminated refrigerant or PAG oil. Perform the following procedure:

IMPORTANT:  The filter inside the J 45268-1 is serviceable. Remove and discard the check valve from the filter.

9.1.

Service the filter with AC P/N GF 470, before each flush.
Connect the J 45268-1 flush filter to the suction port of the J 45268-4 flush adapter.

9.2.

Connect the blue hose from the J 43600 to the J 45268-1 flush filter adapter.

9.3.

Connect the red hose from the J 43600 to the J 45268-5 flush adapter.

10. Reverse flow refrigerant flushing is recommended for desiccant bag failure.

Perform the following procedure and replace the accumulator when the flush procedure is complete.

IMPORTANT:  The filter inside the J 45268-1 is serviceable. Remove and discard the check valve from the filter.

10.1. Service the filter with AC P/N GF 470, before each flush.

Connect the J 45268-1 flush filter to the discharge port of the J 45268-5 flush adapter.

10.2. Connect the blue hose from the J 43600 to the J 45268-1 flush filter adapter.