14. Connect the BPMV supply hose quick connect (1).

Ensure the supply hose quick connect is fully engaged by attempting to pull the supply hose from the inlet fitting.

15. Connect the EBCM electrical connector.
16. Connect the electronic brake control position sensor electrical connector.

17. Tighten the brake modulator manual pressure relief valve (1).

Tighten the valve to 40 Nm (30 lb ft).