Be sure to solder the Positive or striped end of the capacitor to pin T. Electrolytic capacitors must be soldered in the circuit in correct polarity or
they will overheat and fail.

^

Solder the capacitor to the removed wiring harness pins for circuits 751 and 705, not to the display panels.

^

If either display panel has been replaced with the new part numbers, see above, do not install a capacitor on the harness to that panel. The new part
numbers already incorporate a capacitor on the circuit board.

5.

Tape the capacitor leads to the wiring harness circuits 705 and 751. Be sure to completely insulate the capacitor leads.

6.

Reinstall terminals into the appropriate connector.

7.

Reconnect and reinstall the fuel data center and climate control panel.

8.

Reinstall the instrument cluster trim plates.

For warranty purposes use Labor Operation T6370 at .8 hour.