Seville V8-300 4.9L (1991)
indicate the command and output terminal voltage.
A brief summary of each output is provided below:
BO00
The "CYCLE NONE" display will not display "HI" or "LO" as this is a resting spot where no outputs will be cycled.
BO03
The Retained Accessory Power (RAP) relays display is "LO" when the relays are on (energized).
BO04
The courtesy relay display is "LO" when the relay is on (energized).
BO05
The twilight relay display is "LO" when the relays are on (energized) lights on.
BO06
The HI/LO beam relays display is "LO" when the relays are on (energized) hi beams on.
BO07
The daytime running light relay display is "LO" when the relays are on (energized).
Override
BS00
This test will display "NONE" as no overrides are active at this point.
BS01
The program number override can be controlled from "O" (Max A/C) to "98" (Max heat). The display will hold the override value upon
release of the buttons.
BS02
The Vacuum Fluorescent (VF) dimming override can be controlled from "O" (Max dim) to "99" (Max bright). The display will hold the
override value upon release of the buttons.
BS03
The incandescent bulb-dimming override can be controlled from "O" (Max dim) to "99" (Max bright) if the park lamps have been illuminated.
The display will hold the override value upon release of the buttons.
BS08
The option 1 override will control the export status bit according to the chart below:
If vehicle is equipped with:
Add
USA car (all except Canadian and export cars)
128
Heated windshield (option code C50)
32
Seville
1
Export displays ( option code MAE)
64
Unleaded telltale disable (opt. code NM8,MAJ)
16
Low fuel telltale disable (option code MAE)
2
To override, press "Warmer" to increase or "Cooler" to decrease the value. To overwrite the value in the EEPROM, hold the "Econ" and the
"Inst Econ" buttons for 3 seconds.
BS09
The option 2 override will be "2" for all cars.