Seville V8-300 4.9L (1991)
^
Place the transmission in park and turn ignition off.
IMPORTANT:
Because of the load differences on the engine with A/C on versus A/C off, learning must be allowed under both conditions.
11. Perform TPS learn:
^
Turn ignition on (engine not running).
^
Enter diagnostics.
^
Turn ignition off.
^
Wait a minimum of 20 seconds.
^
Turn ignition on (engine not running).
^
Re-enter diagnostics.
^
Turn ignition off.
^
Wait a minimum of 20 seconds.
For warranty purposes use Labor Operation T6527 at 1.3 hours.