chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

A/C - Modes Change/Slow Vacuum Valve Operation|Page 3341 > < A/C - Modes Change/Slow Vacuum Valve Operation
Page 2
background image

Parts are currently available from GMSPO.
PROCEDURE:

1.

Remove the air cleaner.

2.

Disconnect the HVAC vacuum supply tube at the front of the TBI unit, as shown in Figure 1.

3.

Install the 1 1/4 in. length of hose on the black side of the check valve.

4.

Install the hose and check valve to the TBI unit, as shown in Figure 1.

5.

Connect the HVAC vacuum supply tube to the check valve, as shown in Figure 1.

6.

Reinstall the air cleaner.

7.

Check the HVAC system for the function and proper mode operations.

Labor Operation Number:

T1591

Labor Time:

0.4 Hours

A/C - Modes Change/Slow Vacuum Valve Operation|Page 3341 > < A/C - Modes Change/Slow Vacuum Valve Operation