Malibu Classic L4-2.2L (2008)
Hose/Line HVAC: Service and Repair
Liquid Line Replacement
Liquid Line Replacement
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Remove the refrigerant pressure sensor wire harness connector.
3. Remove the refrigerant pressure sensor.
4. Remove the liquid line bracket bolt.
5. Remove the air cleaner assembly.
6. Remove the surge tank from the surge tank bracket.
7. Remove the suction hose and liquid line nut from the thermal expansion valve (TXV).
8. Remove the suction hose and liquid line from the TXV.