chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Hybrid Controls|Page 7536 > < Hybrid Controls|Page 7534
Page 11
background image

7. Apply the specified pressure with J 24460-01.

Apply 20 psi (138 kPa) pressure.

8. Monitor the pressure tester gauge for 5 minutes and ensure that pressure remains at the specified value.

*

If the specified pressure cannot be maintained, disassemble the drive motor generator control module assembly and replace the coolant seals.

*

If pressure remains at the specified value, proceed to the next step.

9. Remove all GE-48494 components.

10. Remove the PIM cover retaining bolts (1).
11. Remove the PIM electronics cover (2).

Caution:  Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic
circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.

Hybrid Controls|Page 7536 > < Hybrid Controls|Page 7534