chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Heating and Ventilation|Page 7125 > < Heating and Ventilation
Page 2
background image

1. Disconnect the fresh/recirculate control cable from the clip (1) and the door at the blower case.
2. Set the fresh/recirculate lever to the RECIRC position.
3. At the blower case, hold the door fully downward and install the cable to the clip.
4. Inspect the fresh/recirc lever for smooth operation.
5. Ensure that the fresh/recirc lever stops at the correct positions.

Heating and Ventilation|Page 7125 > < Heating and Ventilation