chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Intake Manifold > < Oil Pump, Engine|Service and Repair|Page 1512
Page 3
background image

Fig. 39  Measuring Clearance Between Rotors & Case

7.

Place a straightedge across face of CCC between bolt holes. If a feeler gauge of .004 inch (.102 mm) or more can be inserted between rotors and
straightedge, replace pump assembly.

8.

Inspect oil pressure relief valve plunger for scoring and free operation in it's bore. Small marks can be removed with 400-grit wet or dry sand
paper.

9.

Relief valve spring has a free length of approximately 1.95 inch (49.5 mm) and should test between 19.5-20.5 pounds when compressed to 1-1/32
inch (34 mm). Replace spring that does not meet specifications.

ASSEMBLY & INSTALLATION

1.

Assemble oil pump as shown using new parts as required.

2.

Torque oil pump cover screws to specifications.

3.

Prime oil pump prior to installation by filling rotor cavity with engine oil.

4.

Refer to procedure, TIMING CHAIN COVER & OIL SEAL to install timing chain case cover.

Intake Manifold > < Oil Pump, Engine|Service and Repair|Page 1512