Drain and refill - Refilling - Bleeding: Cooling system
- Make
- Citroën
- Model
- AX Factory Workshop Manual
- Year
- 1986–1998
- Section
- Cooling system › Drain and refill - Refilling - Bleeding: Cooling system
Drain and refill - Refilling - Bleeding: Cooling system
ESSENTIAL: Observe the safety and cleanliness recommendations.
CAUTION: Refer to the vehicle’s servicing schedule for the coolant checking interval.
Check the pH of the coolant; Using reactive strips.
N.B.: The pH value of the coolant should be between 7 and 8.
Replace the coolant if the pH value is out of tolerance.
1. Tooling
| Tool | Reference | Designation |
|---|---|---|
| [01102] | Tool for filling the cooling system by vacuum |
| [0173] | Bayonet filling cylinder |
| [0173-B] | Adaptor / extension for bayonet filling cylinder [0173] |
| [0173-C] | blocking rod for filling cylinder |
| [0173-2] | Screw-fit filling cylinder (without extension) |
| [0165-2] | Cable pliers for flexible clips |
2. Draining the cooling system
CAUTION: The draining operation is carried out with the engine cold.
Put the vehicle on a hoist.
Remove:
- The protective panel under the engine (according to equipment)
- The de-aeration chamber plug (Carefully)
N.B.: Place a clean tray underneath the engine to recover the coolant.
Uncouple the pipe (1) (at "a"); Using tool [0165-2].
Open the bleed screws located on the coolant outlet housing and the heater pipe.
Allow the coolant to run out.
Drain the cylinder block (if necessary).
CAUTION: If the tool for filling the cooling system by vacuum [01102] is used, measure the quantity of coolant drained.
3. Filling the cooling system
CAUTION: If the cooling system is contaminated, rinse with clean water.
CAUTION: Always use new coolant.
CAUTION: Each filling operation must always be followed by a cooling system degas operation.
3.1. Filling the cooling system by gravity
Connect the hose (1) (at "a"); Using tool [0165-2].
N.B.: Refit new clips ().
"A": Fitting with filling cylinder offset; Using the tools [0173], [0173-B], [0173-C].
"B": Fitting with filling cylinder direct; Using tool [0173-2].
Fit the filling cylinder, blank and adaptor assembly on the expansion chamber (according to assembly).
Open the rod on the filling cylinder.
Slowly fill the cooling system with clean coolant.
Close the bleed screw when the fluid is flowing freely without any air bubbles.
N.B.: The filling cylinder should be filled to the 1 litre mark for correct bleeding of the heater matrix.
3.2. Filling using the tool for filling the cooling system by vacuum
CAUTION: Always use new coolant.
Connect the hose (1) (at "a"); Using tool [0165-2].
N.B.: Refit new clips ().
Close the bleed screw.
Put the equipment for filling by vacuum [01102] in place on the expansion bottle.
CAUTION: To avoid entry of air into the circuit, provide for 20 % additional coolant.
Prepare a receptacle of coolant containing the quantity of fluid drained + 20 %.
N.B.: The receptacle must be positioned slightly lower than the equipment for filling by vacuum.
Place the cooling circuit under a vacuum to reach -0,9 bar (diagram "C"):
- Wait 10 seconds and check that the value obtained does not drop
- Fill the cooling circuit completely and wait for the return to 0 bar (diagram "D")
N.B.: The quantity of coolant filled should correspond to the quantity of fluid drained.
Repeat the operation until the cooling system is full (if necessary).
CAUTION: Remove the equipment for filling by vacuum [01102] and rinse the assembly with clean water.
4. Degassing and checking the cooling system
Fit the charging cylinder, closer and adaptor assembly on the expansion bottle, in the case of draining using the tool for filling by vacuum [01102].
Open the rod on the filling cylinder.
Start the engine.
N.B.: The air conditioning control should not operate during this phase.
4.1. All engines except emission standard EURO 6
Keep the engine speed at 1500 - 2000 rpm, up to the second cooling cycle (cooling fan(s) cutting in and out).
CAUTION: Check that there are no coolant leaks.
4.2. Diesel engine Euro 6
The cutting in of the fan assembly for 10 seconds indicates the switch to after sales degas mode.
Accelerate to an engine speed above 2300 rpm for more than 10 seconds to switch to degas mode.
Maintain the engine speed at 2500 rpm until the fan assembly cuts in again.
4.3. Degassing and checking the cooling system (continued)
CAUTION: Check that the level of coolant in the filling cylinder is sufficient.
Stop the engine.
ESSENTIAL: Do not remove the filling cylinder while the engine is hot.
Leave the engine to cool.
Blank the filling cylinder using the blocking rod.
Remove the filling cylinder, plug and adapter assembly.
Check the coolant level when cold.
Top up the coolant to the "max" level (Cold).
CAUTION: Do not fill the system past the max mark.
Refit and tighten the cap on the header tank.
CAUTION: Check that the cooling system filler cap is locked (For bayonet cap).
Refit:
- The protective panel under the engine (according to equipment)
- The vehicle to its wheels
Parts & tools for this job For 1986 Citroën AX
- FLUIDCoolantSearch: Citroën coolant antifreeze
- PARTThermostatSearch: Citroën AX 1986 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester
As an Amazon Associate we earn from qualifying purchases.