General: Additional and independent heating systems
- Make
- Citroën
- Model
- Berlingo Factory Workshop Manual
- Year
- 1996–2002
- Section
- Cooling system › General: Additional and independent heating systems
General: Additional and independent heating systems
2 units are used depending on the engines.
1. Additional heating
Given the high efficiency of the engine, the temperature in the passenger compartment must be helped to rise during cold weather.
An additional heater supplied with diesel fuel and mounted on the cooling system serves to provide the extra heat to the air conditioning heater matrix.
The injection ECU, when the engine is started, calculates the requirement for heat in the passenger compartment as a function of the inlet air temperature and the engine coolant temperature.
The injection ECU commands the deployment of the heater in the following conditions:
- Engine operating for 60 seconds
- Engine speed above 700 rpm
- Battery voltage greater than 12 volts (positive electrical balance)
- Coolant temperature greater than -40°C
The additional heating is switched off when the temperature conditions so allow (curve).
Ta = Intake air temperature.
Te = Coolant temperature.
A = Example 1.
B = Example 2.
A Heating authorisation zone.
Example 1:
- Engine coolant temperature = 40 °C
- Intake air temperature = -10 °C
- The temperature conditions are within the additional heating’s operating zone
N.B.: Depending on the vehicles the conditions triggering the additional heater can be different.
Example 2:
- Engine coolant temperature = 60 °C
- Intake air temperature = 15 °C
- The temperature conditions are outside the operating zone: There is no additional heating
1.1. Additional heating control
1320: injection ECU.
8098: additional heating.
8091: Additional heater control relay.
1.2. Fuel supply system
The heater is supplied with diesel fuel by a metering pump controlled by pulses by the heater and placed on the heater mounting.
The fuel is provided from the injection return piping.
1.3. Coolant circuit
The fluid is circulated by the engine’s water pump.
2. Independent heating
This type of heater unit is fitted on electric vehicles because there is no heat released by the engine.
The heating of the passenger compartment, the demisting and de-icing functions of the windscreen are provided by a heat exchanger identical to that of an internal combustion engined vehicle.
The heat source required to heats the coolant circulating in this heat exchanger is produced by an independent heater operating on petrol.
2.1. Independent heater control
It is turned on by a handle or a switch.
To the driver, operation is similar to a conventional vehicle.
An indicator light shows that the system is working, The indicator light is located close to the handle or on the control switch.
2.2. Fuel supply system
The petrol supply circuit is made up of the following components:
- The fuel tank is located under the floor panel, at the RH rear of the vehicle
- A metering pump controlled by pulses by the heater
The fuel tank has a capacity of 10 litres.
The tank is filled by the conventional opening on the right-hand rear wing with 95 or 98 leadfree petrol.
2.3. Loss of prime prevention device
A safety device preventing the fuel circuit from losing prime prime automatically cuts the control of the heater when the fuel level is too low.
The loss of prime prevention device is made up of the following components:
- Double sensor gauge incorporating a thermistor and a switch connected to a float
- Double relay
Function:
- When the fuel uncovers the thermal resistance, a warning indicator light on the instrument panel comes on (there is still about 0,5 litres available in the tank)
- When the float operates the switch of the gauge, the double relay is then controlled which automatically cuts the control of the heater
- The heater stops even though the control (handle or pushbutton) is in the "ON" position and the heater operating indicator goes off
- Operating the control again or switching the ignition off allows the heating to be started again temporarily
2.4. Coolant circuit
The fluid is circulated by an electrical water pump controlled by the heater.
The water pump is fixed to the body of the heater.
2.5. Schematic diagram
Press button including switch, indicator, light (c) (according to the assembly operations).
D: Heater control switch.
E: Heater operating indicator.
F: Heater control lighting.
G: Double relay.
0004: Minimum level warning indicator.
8098: Heater.
8093: Fuel metering pump.
4310: Double contact gauge.
Parts & tools for this job For 1996 Citroën Berlingo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Citroën Berlingo 1996 cabin filter
As an Amazon Associate we earn from qualifying purchases.