01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Electrical - general20 Starting and charging21 Instruments and warning lamps22 Locking, alarm and airbags23 Heating, air conditioning and audio
Citroën Berlingo Factory Workshop Manual (1996-2002)20 · Starting and charging
20 · Electrical

Data: Traction battery charges

Make
Citroën
Model
Berlingo Factory Workshop Manual
Year
1996–2002
Section
Battery › Data: Traction battery charges
Starting and chargingData: Traction battery charges

Data: Traction battery charges

Citroën Berlingo · Data - identification · Ref. E1AB31P0

Applies to: SA18

ESSENTIAL: Only those personnel who have received special training on electric vehicles are qualified to operate on the vehicle (please observe the regulations that are in force in the country concerned).

1. Battery charge options

The 3 options for recharging the traction battery are as follows:

  • At home using an earthed domestic socket of 230 volts/16 amps
  • At terminals located on the public highway, installed at special parking places
  • At service station rapid charging terminals

The vehicle is delivered with 2 types of charging lead:

  • Charging lead for public highway socket (blue)
  • Charging lead for domestic socket (black colour)

Composition of the charging lead:

  • A 230 volt mains plug with 2 male pins, live and neutral, and an earth
  • A special plug to be connected to the charging socket, incorporated in the front right vehicle wing

N.B.: The mains plug also has an additional pin, offset and specific, for checking the earthing of the vehicle on connection to sockets on terminals on the public highway.

2. Charging socket plug

It is possible to gain access to the charging socket after opening the flap.

The flap is opened from inside the vehicle.

Figure e1ap041c

(1) Power contact (+) rapid charge (*).

(2) Power contact (-) rapid charge (*).

(3) Earth connection.

(4) Plug presence information.

(5) Pilot line earth.

(6) phase.

(7) 230 volts neutral.

(8) 230 volts live.

(9) phase.

(10) Line L.

(11) Line K rapid charge (*).

N.B.: (*) According to equipment.

During charging, the energy gauge continuously indicates the battery charge status.

The charge begins as soon as the charging plug is connected, on condition that the flap is closed (opening the flap during charging stops charging).

At the beginning of the charge, the 4 direction indicator lamps come on continuously for 10 seconds, indicating the immediate start of charging.

When the coolant temperature is high, charging is delayed and the four direction indicators flash for 10 seconds.

N.B.: Charging is carried out with the ignition switched off; the "STOP" warning lamp comes on when the charging plug is connected.

3. Charge curves

The battery can be charged in the 4 following ways:

  • Normal charge
  • Equalisation charge
  • Maintenance charge
  • Initialisation charge

3.1. Normal charge

This charge is carried out at home using a 230 volt mains socket or using a terminal on the public highway.

Figure d1ap01nc

N.B.: The duration of the charge C1 period depends on the charging state of the battery when it is being charged.

The maximum duration of charge C1 depends on the programmed mains current value (see the table below).

Mains current
Charging current I(A)Maximum duration of charge C1
10A11,5 hr
13A9,5 hr
14A9 hr

In addition to the "normal" charge, an over-charge phase C2 with a current of approximately 5 amperes, fixed at 15% of the "normal" charge, is used to keep the battery capacity at its maximum.

N.B.: When one or more normal charges are interrupted (before over-charge C2): When the next normal charge is carried out, the duration of the over-charge is increased to take into account the deficit of amps/hours.

N.B.: Over-charge C2 causes water consumption.

The amp-hours charged and "over-charged" can be counted by the ECU.

3.2. Equalisation charge

This charge is started automatically by the ECU following every charged 1000 Ah registered during "normal" charges.

This charge allows the voltages of the 27 6-volt monoblocs to be "equalised".

Figure d1ap01pc

This charge is made up of the 2 following phases:

  • A "normal" charge C1
  • An over-charge C3 with a current of 5 amperes fixed at 5 hours

N.B.: This over-charge can be started by the diagnostic equipment.

3.3. Maintenance charge

This charge is carried out in the workshop every 10000 km or when the "low battery water level" warning lamp comes on.

N.B.: If the water is not topped up at this point, the "electronic fault" warning lamp comes on. After charging, it is necessary to top up with distilled water and ensure that the warning lamp on the dashboard goes out.

Figure d1ap01qc

This charge is made up of the 3 following phases:

  • A "normal" charge C1
  • An over-charge C4 with a current of 10 amperes fixed at 5 hours
  • A charging phase with a pulsed current of 10 amperes for 5 minutes every 25 minutes for 72 hours

3.4. Initialisation charge

This charge is necessary when one of the following components is replaced:

  • Traction battery compartment
  • Computer
  • Electronic unit

N.B.: This charge is obligatory, when the ECU or charger pack are replaced, if there is no dialogue between the vehicle and the diagnostic unit.

This charge consists of resetting the ECU Ah counters to zero and equalising the voltages between monoblocs.

N.B.: This over-charge can be started by the diagnostic equipment.

Figure d1ap01rc

This charge is made up of the 2 following phases:

  • A charge C5 with a current of 10 amperes for 12 hours
  • An over-charge phase with a pulsed current of 10 amperes for 5 minutes every 25 minutes for 72 hours

N.B.: After charging, it is necessary to top up with distilled water and ensure that the warning lamp on the dashboard goes out.

N.B.: The "STOP" warning lamp comes on at + after ignition with a programmed maintenance or initialisation charge.

3.5. Rapid charge (according to equipment)

This charge is carried out at a service station.

N.B.: Use the special lead (supplied with the vehicle) to connect the vehicle charging unit to the charging terminal.

The traction battery is charged with a current of 150 amperes.

The duration of this charge can be programmed by the user (20 minutes is enough to recharge the traction battery to 50% of its capacity).

This charge can not be carried out if there are any faults present.

4. Battery charges in exceptional cases

Depending on the condition of the traction battery, the ECU is able to start the 2 following types of preliminary charges:

  • A charge with a low current (200 mA) when the battery voltage is between 10 volts and 80 volts
  • A charge with a current of 10 amperes for 12 minutes when the battery voltage is between 80 volts and 105 volts