Removing - Refitting: Oxygen sensor
- Make
- Citroën
- Model
- C1 Factory Workshop Manual
- Year
- 2005–2014
- Section
- Emission control › Removing - Refitting: Oxygen sensor
Removing - Refitting: Oxygen sensor
ESSENTIAL: Ensure that the precautions relating to safety and cleanliness are adhered to.
CAUTION: For any operation on an oxygen sensor: The oxygen sensor connector must be cleaned dry. It is strictly prohibited to use solvents or contact greases for cleaning the connectors of the upstream and downstream oxygen sensors.
ESSENTIAL: Wait at least one hour before carrying out any work on the exhaust line (engine hot).
1. Tooling
| Tool | Part number | Description |
|---|---|---|
| [4386-T] | slit socket 22 mm |
2. Location
(1) Upstream oxygen sensor.
"a" Connector (Upstream oxygen sensor).
(2) Downstream oxygen sensor.
"b" Connector (Downstream oxygen sensor).
3. Removing
Disconnect the ancillaries battery.
3.1. Upstream oxygen sensor
Disconnect the connector "a".
Remove: The upstream oxygen sensor (1); Using tool [4386-T].
3.2. Downstream oxygen sensor
Raise the vehicle using a lifting bench.
Disconnect the connector "b".
Remove: The downstream oxygen sensor (2); Using tool [4386-T].
4. Refitting
CAUTION: Adhere to the tightening torques.
4.1. Downstream oxygen sensor
Refit: The downstream oxygen sensor (2); Using tool [4386-T].
Tighten: The downstream oxygen sensor (2).
Connect the connector "b".
4.2. Upstream oxygen sensor
Refit: The upstream oxygen sensor (1); Using tool [4386-T].
Tighten: The upstream oxygen sensor (1).
Connect the connector "a".
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
Check the functioning of the different pieces of equipment.
Parts & tools for this job For 2005 Citroën C1
- PARTOxygen sensorSearch: Citroën C1 2005 oxygen sensor
- TOOLOxygen sensor socketSearch: oxygen sensor socket
- TOOLOBD2 scannerSearch: OBD2 scanner