Removing - refitting: Coolant outlet housing (DV4TD)
- Make
- Citroën
- Model
- C3 (A51) Factory Workshop Manual
- Year
- 2016–2024
- Section
- Cooling system › Removing - refitting: Coolant outlet housing (DV4TD)
Removing - refitting: Coolant outlet housing (DV4TD)
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Tooling
| tool | Reference | Designation |
|---|---|---|
| [0165-2] | Cable pliers for flexible clips |
2. Removing
Disconnect the battery.
Drain the cooling system.
Disconnect the air flow sensor connector (as "a").
Remove:
- The air inlet neck (3)
- The bolt (4)
- The air duct (2)
Disconnect the engine temperature sensor connector (as "b").
Uncouple the hoses (5), (6), (7) and (8); Using tool [0165-2].
Remove:
- The bolts (9)
- The thermostat (10)
3. Refitting
CAUTION: Adhere to the tightening torques.
CAUTION: If removing-refitting the engine temperature sensor, Replace the seal of the engine temperature sensor with a seal that is pre-lubricated.
N.B.: The coolant outlet unit (10) contains the thermostatic regulator.
Fit the coolant outlet elbow (10) with a new joint.
CAUTION: Ensure that the seal is positioned correctly in its housing.
Refit the bolts (9).
Join the hoses (5), (6), (7), (8).
Connect the connector (as "b").
Refit:
- The air duct (2)
- The bolt (4)
- The air inlet neck (3)
- The fuel filter (1)
Connect the connector (as "a").
Fill and bleed the cooling system.
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Reconnect the battery.
Parts & tools for this job For 2016 Citroën C3
- FLUIDCoolantSearch: Citroën coolant antifreeze
- PARTThermostatSearch: Citroën C3 2016 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester
As an Amazon Associate we earn from qualifying purchases.