ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Location
(1) Variable timing electrovalve (Exhaust).
(2) Variable timing electrovalve (Inlet).
(3) Eccentric shaft actuator.
N.B.: Removing the variable timing (inlet) solenoid valve (2) or the eccentric shaft actuator (3) necessitates removing the air filter housing.
2. Variable timing electrovalve (Exhaust)
2.1. Removing
ESSENTIAL: Allow the exhaust line to cool: Risk of burns.
Remove the battery cover (according to equipment).
Disconnect the battery.
Disconnect the connector (at "a").
CAUTION: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.
Remove:
- The (4) bolt
- The variable distribution solenoid valve (Exhaust) (1)
2.2. Refitting
CAUTION: Adhere to the tightening torques.
CAUTION: Clean the sensor sealing zone and check that it is free of knocks and scratches.
Refit:
- The variable distribution solenoid valve (Exhaust) (1) (equipped with a new seal)
- The (4) bolt
Connect the connector (at "a").
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Reconnect the battery.
Refit the battery cover (according to equipment).
Top up the engine oil (If necessary).
3. Variable timing electrovalve (Inlet)
3.1. Removing
Uncouple the vacuum pipe () (at "b").
Remove the battery cover (according to equipment).
Disconnect the battery.
Remove:
- The air intake resonator (9)
- The air duct (10)
- The (11) bolt
- The air resonator (7)
Raise and move aside: The engine management ECU (8) (according to equipment).
Remove:
- The bolts (6)
- The (12) bolt
- The air filter cover (5)
- The filter element
Remove:
- The bolts (14)
- The intermediate filter support (13)
- The air filter housing (15)
- The inlet air union (16)
Disconnect the connector (at "c").
CAUTION: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.
Remove:
- The (17) bolt
- The variable distribution solenoid valve (Inlet) (2)
3.2. Refitting
CAUTION: Adhere to the tightening torques.
CAUTION: Clean the sensor sealing zone and check that it is free of knocks and scratches.
Refit:
- The variable distribution solenoid valve (Inlet) (2) (equipped with a new seal)
- The (17) bolt
Connect the connector (at "c").
Refit:
- The inlet air union (16)
- The air filter housing (15)
- The intermediate filter support (13)
- The bolts (14)
- The filter element
- The air filter cover (5)
- The (12) bolt
- The bolts (6)
- The engine management ECU (8) (according to equipment)
- The air resonator (7)
- The (11) bolt
- The air duct (10)
- The air intake resonator (9)
Couple the vacuum pipe (at "b").
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Reconnect the battery.
Refit the battery cover (according to equipment).
Check the oil level (If necessary).
4. Eccentric shaft actuator
ESSENTIAL: Never supply the actuator directly: risk of injury. The actuator must only be supplied by the engine management ECU with the original connector, following correct fitting on the cylinder head.
4.1. Removing
Uncouple the vacuum pipe () (at "b").
Remove the battery cover (according to equipment).
Disconnect the battery.
Remove:
- The air intake resonator (9)
- The air duct (10)
- The (11) bolt
- The air resonator (7)
Raise and move aside: The engine management ECU (8) (according to equipment).
Remove:
- The bolts (6)
- The (12) bolt
- The air filter cover (5)
- The filter element
Remove:
- The bolts (14)
- The intermediate filter support (13)
- The air filter housing (15)
- The inlet air union (16)
Unplug: The eccentric shaft actuator (3) connector (at "e").
CAUTION: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.
Remove:
- The bolts (18)
- The eccentric shaft actuator (3); Rotate the shaft (at "d"); Using a size 4 allen key (anti clockwise)
- The seal (19)
4.2. Refitting
CAUTION: Adhere to the tightening torques.
N.B.: Clean the sensor sealing zone and check that it is free of knocks and scratches.
Refit:
- The seal (19) (New)
- The eccentric shaft actuator (3); Rotate the shaft (at "d"); Using a size 4 allen key (Clockwise)
Check that the eccentric shaft actuator (3) is locked against the cylinder head.
Tighten the bolts (18).
CAUTION: Check that the actuator flange is not distorted.
Connect: The eccentric shaft actuator (3) connector (at "e").
Refit:
- The inlet air union (16)
- The air filter housing (15)
- The intermediate filter support (13)
- The bolts (14)
- The filter element
- The air filter cover (5)
- The (12) bolt
- The bolts (6)
- The engine management ECU (8) (according to equipment)
- The air resonator (7)
- The (11) bolt
- The air duct (10)
- The air intake resonator (9)
Couple the vacuum pipe (at "b").
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Reconnect the battery.
Refit the battery cover (according to equipment).
Check the oil level (If necessary).