Check: Air supply circuit
- Make
- Citroën
- Model
- C3 Picasso Factory Workshop Manual
- Year
- 2009–2017
- Section
- Air and fuel supply › Check: Air supply circuit
Check: Air supply circuit
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Recommended tools
[1] vacuum-pressure manual pump FACOM DA 16 (kit 4530).
2. Check
2.1. Vacuum pump
Uncouple the vacuum pipe () (as "a").
Connect the tool [1] to the vacuum pump (1) (at "a").
Start the engine.
Wait 30 seconds.
The vacuum value should be 0,9 ± 0,1 bar at idling speed.
N.B.: The exhaust gas recycling valve is not linked to the air supply circuit. The engine ECU controls the EGR electrovalve.
2.2. Turbocharger wastegate valve (GARRETT)
Uncouple the vacuum pipe (at "b").
Connect the tool [1] on the turbocharging regulation valve of the turbocompressor (2) (at "b").
Apply a vacuum of approximately 0,8 bar.
The rod "c" should move 12 ± 2 mm.
2.3. Turbocharger wastegate valve (MHI)
Uncouple the vacuum pipe (at "b").
Connect the tool [1] on the turbocharging regulation valve of the turbocompressor (2) (at "b").
Apply a vacuum of approximately 0,8 bar.
The rod "c" should move 6 ± 2 mm.
Parts & tools for this job For 2009 Citroën C3 Picasso
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit
As an Amazon Associate we earn from qualifying purchases.