Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Interior trim20 Electrical - general21 Starting and charging22 Wiring harnesses23 Instruments and warning lamps24 Locking, alarm and airbags25 Electrical - driver assistance systems26 Heating, air conditioning and audio
Citroën C4 Factory Workshop Manual (2004-2010)01 · Engine
01 · Engine

Removing - Refitting: Actuator / Variable timing electrovalve

Make
Citroën
Model
C4 Factory Workshop Manual
Year
2004–2010
Section
Crankshaft › Removing - Refitting: Actuator / Variable timing electrovalve
EngineRemoving - Refitting: Actuator / Variable timing electrovalve

Removing - Refitting: Actuator / Variable timing electrovalve

Citroën C4 · Removal-fitting · Ref. B1EG0112P0

Applies to: 1.6 vti 16V 120 (EP6)

ESSENTIAL: Observe the safety and cleanliness recommendations.

1. Location

Figure b1bm0drd

(1) Variable timing electrovalve (Exhaust).

(2) Variable timing electrovalve (Inlet).

(3) Eccentric shaft actuator.

N.B.: Removal of the electrovalve (2) or of the actuator (3) requires removal of the air filter housing.

2. Variable timing electrovalve (Exhaust)

2.1. Removing

CAUTION: Allow the exhaust line to cool.

Disconnect the battery.

Figure b1em044d

Disconnect the connector (as "a").

N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.

Remove:

  • The (4) bolt
  • The (1) variable distribution solenoid valve

2.2. Refitting

N.B.: Clean the sensor sealing zone and check that it is free of knocks and scratches.

Refit:

  • The (1) variable distribution solenoid valve   (equipped with a new seal)
  • The (4) bolt; Tighten to 0,9 ± 0,1 daN.m

Connect the connector (as "a").

CAUTION: Perform the operations to be carried out following reconnection of the battery.

Reconnect the battery.

Check the oil level.

3. Variable timing electrovalve (Inlet)

3.1. Removing

Disconnect the battery.

Figure b1bm1d1d

Unscrew:

  • The bolts (5)
  • The (7) bolt

Remove:

  • The air deflector (10)
  • The resonator (11)
  • The (8) bolt
  • The air union (9)
  • The air filter cover (6)
  • The filter element
Figure b1hm0xzd

Remove:

  • The bolts (13)
  • The intermediate filter support (12)
  • The air filter housing (14)
  • The inlet air union (15)

N.B.: Remove the air filter housing between the battery and the engine.

Figure b1em047d

Disconnect the connector (as "b").

N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.

Remove:

  • The (16) bolt
  • The (2) variable distribution solenoid valve

3.2. Refitting

N.B.: Clean the sensor sealing zone and check that it is free of knocks and scratches.

Refit:

  • The (2) variable distribution solenoid valve   (equipped with a new seal)
  • The (16) bolt; Tighten to 0,9 ± 0,1 daN.m

Connect the connector (as "b").

Refit:

  • The inlet air union (15)
  • The air filter housing (14)
  • The intermediate filter support (12)
  • The bolts (13)
  • The filter element
  • The air filter cover (6)

Tighten:

  • The bolts (5)
  • The (7) bolt

Refit:

  • The air union (9)
  • The (8) bolt; Tighten to 0,8 ± 0,1 daN.m
  • The resonator (11)
  • The air deflector (10)

CAUTION: Perform the operations to be carried out following reconnection of the battery.

Reconnect the battery.

Check the oil level.

4. Eccentric shaft actuator

ESSENTIAL: Never supply the actuator directly: risk of injury. The actuator must only be supplied by the engine management ECU with the original connector, following correct fitting on the cylinder head.

4.1. Removing

Disconnect the battery.

Figure b1bm1d1d

Unscrew:

  • The bolts (5)
  • The (7) bolt

Remove:

  • The air deflector (10)
  • The resonator (11)
  • The (8) bolt
  • The air union (9)
  • The air filter cover (6)
  • The filter element
Figure b1hm0xzd

Remove:

  • The bolts (13)
  • The intermediate filter support (12)
  • The air filter housing (14) (Remove the air filter housing between the battery and the engine)

N.B.: Remove the air filter housing between the battery and the engine.

Figure b1em048d

Unplug: The actuator connector (as "d").

N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.

Remove:

  • The bolts (17)
  • The actuator (3); Turn: The shaft (as "c"); Using a size 4 allen key   (anti clockwise)
  • The seal (18)

4.2. Refitting

N.B.: Clean the sensor sealing zone and check that it is free of knocks and scratches.

Refit:

  • The seal (18)   (new)
  • The actuator (3); Turn: The shaft (as "c"); Using a size 4 allen key   (clockwise)
  • The bolts (17); Tighten to 0,8 ± 0,1 daN.m

Connect: The actuator connector (as "d").

Refit:

  • The inlet air union (15)
  • The air filter housing (14)
  • The intermediate filter support (12)
  • The bolts (13)
  • The filter element
  • The air filter cover (6)

Tighten:

  • The bolts (5)
  • The (7) bolt

Refit:

  • The air union (9)
  • The (8) bolt; Tighten to 0,8 ± 0,1 daN.m
  • The resonator (11)
  • The air deflector (10)

CAUTION: Perform the operations to be carried out following reconnection of the battery.

Reconnect the battery.

Check the oil level.

Parts & tools for this job For 2004 Citroën C4

As an Amazon Associate we earn from qualifying purchases.