ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Preliminary operations
Depressurise the hydraulic circuit (); Using the diagnostic equipment.
2. Tools to be produced locally
Guide pegs [1] = 4 threaded rods:
- Diameter "A" M6
- "B" = 50mm length
3. Removing
Disconnect the 2 connectors (at "a").
Unclip the electrical harness.
Remove:
- The (2) bolt
- The clip (4)
Uncouple and move aside the hose (3) (at "b").
N.B.: Use a plug to block the hose (3) in order to prevent any entry of impurities into the hydraulic circuit.
Remove the 4 bolts (1).
Position the 4 guide pegs [1] in place of the bolts (1).
CAUTION: Do not use tools, remove the ECU by hand.
Remove the gearbox ECU (5).
N.B.: Significant force is required to detach the ECU from the electro-hydraulic unit.
Remove the bolts (6).
CAUTION: Mark the piloting electrovalves with an indelible felt-tip pen.
Remove:
- The earth plate (8)
- The retaining plate (7)
CAUTION: Do not use tools; Remove the piloting electrovalves by hand, if necessary use a cloth for a better grip.
Remove the piloting electrovalves:
- (9) Control of the clutch (Engraving QPV05)
- (10) Selection control (Engraving OOV04)
- (11) Control for the odd number gears (R, 1, 3, 5) (Engraving PPV05)
- (12) Control for the even number gears (2, 4, 6) (Engraving PPV05)
CAUTION: Take care not to allow impurities to get into the hydraulic circuit.
4. Refitting
Clean the surfaces thoroughly.
Replace the "o" ring seals (at "c").
Refit the piloting electrovalves, respecting the positioning of the lugs (at "d").
Replace the holding plate (7), respecting the direction of fitting (Lug at "e" on the outside and on top).
Refit the ground plate (8).
Replace the bolts (6); Tighten to 0,4 daN.m.
CAUTION: Check the correct alignment of the pins at "f" of the electrovalves and also of the pressure sensor before refitting the ECU.
Fit the guide pegs [1].
Replace the seal on the ECU.
N.B.: Position the thickest side of the seal on the ECU (the thinnest side must be in contact with the piloting actuator).
Refit the ECU (5) by hand until it is in contact with the joint face.
CAUTION: The ECU connection can only withstand one removal-refit; Replace the ECU in the case of a second removal-refit.
Remove the guide pegs [1].
Refit the bolts (1); Tighten the bolts (1) diagonally to 1 m.daN.
Couple up the hose (3) (at "b").
Refit:
- The clip (4)
- The bolt (2); Tighten to 1 daN.m
CAUTION: Coat the base of the ECU connectors with TOTAL N 4128 multipurpose grease (at "a").
Connect the 2 connectors (at "a").
Reclip the electrical harness.
5. Additional operations
The operations to be carried out using the diagnostic tool are as follows:
- The repressurisation of the hydraulic circuit
- The bleeding of the hydraulic circuit
Programme the value of the engine torque transmitted to the clutch.
Parts & tools for this job For 2004 Citroën C4
- PARTClutch kitSearch: Citroën C4 2004 clutch kit
- TOOLClutch alignment toolSearch: clutch alignment tool
- FLUIDGear oilSearch: Citroën C4 manual gearbox oil