ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Location
(1) Variable timing electrovalve.
2. Removing
Disconnect the ancillaries battery.
Disconnect the connector (at "a").
Loosen the clips (2) and (4).
Remove:
- The bolts (5)
- The intermediate union (3)
Unclip the fuel hoses (6) (at "b") (According to equipment).
Pull the fuel piping away (6).
Slacken the clip (8).
Pivot air intake union (7) (In the direction of the arrow).
Disconnect the variable timing electrovalve connector (at "c").
Remove:
- The (9) bolt
- The (1) variable distribution solenoid valve
N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.
3. Refitting
CAUTION: Adhere to the tightening torques.
N.B.: Clean the sealing zone of the electrovalve and check there are no signs of impact or scratching.
Refit:
- The (1) variable distribution solenoid valve
- The (9) bolt
Reconnect connector of the variable timing electrovalve (at "c").
Refit the air inlet union (7).
Secure the fuel hoses (6) (at "b", "c").
Refit:
- The intermediate union (3)
- The bolts (5)
Tighten the clips (2), (4), (8).
Connect the connector (at "a").
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
Check the oil level.
Parts & tools for this job For 2010 Citroën C4
- PARTEngine gasket setSearch: Citroën C4 2010 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.