Removing - Refitting: Actuator / Variable timing electrovalve
- Make
- Citroën
- Model
- C4 Picasso Factory Workshop Manual
- Year
- 2006–2013
- Section
- Crankshaft › Removing - Refitting: Actuator / Variable timing electrovalve
Removing - Refitting: Actuator / Variable timing electrovalve
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Location
(1) Variable timing electrovalve (Exhaust).
(2) Variable timing electrovalve (Inlet).
(3) Eccentric shaft actuator.
N.B.: Removal of the electrovalve (2) or of the actuator (3) requires removal of the air filter housing.
2. Variable timing electrovalve (Exhaust)
2.1. Removing
CAUTION: Allow the exhaust line to cool.
Disconnect the battery.
Disconnect the connector (as "a").
N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.
Remove:
- The (4) bolt
- The (1) variable distribution solenoid valve
2.2. Refitting
N.B.: Clean the sensor sealing zone and check that it is free of knocks and scratches.
Refit:
- The (1) variable distribution solenoid valve (equipped with a new seal)
- The (4) bolt; Tighten to 0,9 ± 0,1 daN.m
Connect the connector (as "a").
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Reconnect the battery.
Check the oil level.
3. Variable timing electrovalve (Inlet)
ESSENTIAL: Observe the safety and cleanliness recommendations.
3.1. Removing
Disconnect the battery.
Unscrew:
- The bolts (5)
- The (7) bolt
Remove:
- The air deflector (10)
- The resonator (11)
- The (8) bolt
- The air union (9)
- The air filter cover (6)
- The filter element
Remove:
- The bolts (13)
- The intermediate filter support (12)
- The air filter housing (14)
- The inlet air union (15)
N.B.: Remove the air filter housing between the battery and the engine.
Disconnect the connector (as "b").
N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.
Remove:
- The (16) bolt
- The (2) variable distribution solenoid valve
3.2. Refitting
N.B.: Clean the sensor sealing zone and check that it is free of knocks and scratches.
Refit:
- The (2) variable distribution solenoid valve (equipped with a new seal)
- The (16) bolt; Tighten to 0,9 ± 0,1 daN.m
Connect the connector (as "b").
Refit:
- The inlet air union (15)
- The air filter housing (14)
- The intermediate filter support (12)
- The bolts (13)
- The filter element
- The air filter cover (6)
Tighten:
- The bolts (5)
- The (7) bolt
Refit:
- The air union (9)
- The (8) bolt; Tighten to 0,8 ± 0,1 daN.m
- The resonator (11)
- The air deflector (10)
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Reconnect the battery.
Check the oil level.
4. Eccentric shaft actuator
ESSENTIAL: Never supply the actuator directly: risk of injury. The actuator must only be supplied by the engine management ECU with the original connector, following correct fitting on the cylinder head.
ESSENTIAL: Observe the safety and cleanliness recommendations.
4.1. Removing
Disconnect the battery.
Unscrew:
- The bolts (5)
- The (7) bolt
Remove:
- The air deflector (10)
- The resonator (11)
- The (8) bolt
- The air union (9)
- The air filter cover (6)
- The filter element
Remove:
- The bolts (13)
- The intermediate filter support (12)
- The air filter housing (14) (Remove the air filter housing between the battery and the engine)
N.B.: Remove the air filter housing between the battery and the engine.
Unplug: The actuator connector (as "d").
N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.
Remove:
- The bolts (17)
- The actuator (3); Turn: The shaft (as "c"); Using a size 4 allen key (anti clockwise)
- The seal (18)
4.2. Refitting
N.B.: Clean the sensor sealing zone and check that it is free of knocks and scratches.
Refit:
- The seal (18) (new)
- The actuator (3); Turn: The shaft (as "c"); Using a size 4 allen key (Clockwise)
- The bolts (17); Tighten to 0,8 ± 0,1 daN.m
Connect: The actuator connector (as "d").
Refit:
- The inlet air union (15)
- The air filter housing (14)
- The intermediate filter support (12)
- The bolts (13)
- The filter element
- The air filter cover (6)
Tighten:
- The bolts (5)
- The (7) bolt
Refit:
- The air union (9)
- The (8) bolt; Tighten to 0,8 ± 0,1 daN.m
- The resonator (11)
- The air deflector (10)
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Reconnect the battery.
Check the oil level.
Parts & tools for this job For 2006 Citroën C4 Picasso
- PARTEngine gasket setSearch: Citroën C4 Picasso 2006 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.