Removing-refitting: Oxygen sensors
- Make
- Citroën
- Model
- C4 Picasso Factory Workshop Manual
- Year
- 2006–2013
- Section
- Emission control › Removing-refitting: Oxygen sensors
Removing-refitting: Oxygen sensors
ESSENTIAL: Observe the safety and cleanliness recommendations.
CAUTION: For any operation on an oxygen sensor: The oxygen sensor connector must be cleaned dry. The use of solvents or contact greases for cleaning the oxygen sensor connector is strictly prohibited.
1. Tooling
| tool | Reference | Designation |
|---|---|---|
| [4386-T] | slit socket 22 mm |
2. Location: Oxygen sensors
(1) upstream oxygen sensor.
(2) Downstream oxygen sensor.
3. Upstream oxygen sensor
3.1. Removing
ESSENTIAL: Wait at least one hour before carrying out any work on the exhaust line.
Disconnect the ancillaries battery.
N.B.: The direction of fitting can vary according to equipment.
Disconnect the connector of the upstream oxygen sensor (1) (at "a").
Detach the connector of the upstream oxygen sensor (1) from the support (at "b").
Remove the upstream oxygen sensor (1); Using tool [4386-T].
3.2. Refitting
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
Refit the upstream oxygen sensor (1); Using tool [4386-T].
Attach the connector of the upstream oxygen sensor (1) to its support (at "b").
Connect the upstream oxygen sensor (1) connector (at "a").
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
4. Downstream oxygen sensor
4.1. Removing
ESSENTIAL: Wait at least one hour before carrying out any work on the exhaust line.
Disconnect the ancillaries battery.
Disconnect the downstream oxygen sensor (2) connector (at "c").
Detach the connector of the downstream oxygen sensor (2) from the support (at "d").
Remove downstream oxygen sensor (2); Using tool [4386-T].
4.2. Refitting
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
Refit downstream oxygen sensor (2); Using tool [4386-T].
Clip the connector on its support (at "d").
Connect the downstream oxygen sensor connector (2) (at "c").
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
Parts & tools for this job For 2006 Citroën C4 Picasso
- PARTOxygen sensorSearch: Citroën C4 Picasso 2006 oxygen sensor
- TOOLOxygen sensor socketSearch: oxygen sensor socket
- TOOLOBD2 scannerSearch: OBD2 scanner
As an Amazon Associate we earn from qualifying purchases.