Check: Air supply circuit
- Make
- Citroën
- Model
- C5 Factory Workshop Manual
- Year
- 2001–2004
- Section
- Air and fuel supply › Check: Air supply circuit
Check: Air supply circuit
ESSENTIAL: Observe the safety and cleanliness recommendations (refer to the brochure: RECOMMENDATIONS - PRECAUTIONS).
1. Recommended tools
[1] FACOM DA 16 type manual pressure and vacuum pump.
2. Check
ESSENTIAL: Respect the safety and cleanliness recommendations that are specific to high pressure diesel injection (HDi) engines.
2.1. Vacuum pump
Connect the tool [1] to the vacuum pump (3).
Start the engine.
The vacuum value should be 0,8 bar at 780 rpm.
2.2. Turbocharging pressure regulation solenoid valve
Connect the tool [1] between the electrovalve (2) and the valve (1).
| Compare the values read with those of the table below | |
|---|---|
| Engine speed | Vacuum value |
| 780 rpm | 0,6 bar |
| 4000 rpm | 0,25 bar |
2.3. Turbocharger wastegate valve
Connect the tool [1] to the valve (1) (pipe with grey mark).
Apply a vacuum of approximately 0,8 bar The shaft "a" should move by 12 ± 2 mm.
2.4. "Swirl" control electrovalve
Connect the tool [1] between the electrovalve (4) and the "swirl" control diaphragm (5).
| Compare the values read with those of the table below | |
|---|---|
| Engine speed | Vacuum value |
| 780 rpm | 0 bar |
| 4000 rpm | 0,6 bar |
2.5. "Swirl" control diaphragm
Connect the tool [1] to the "Swirl" control diaphragm (5).
Apply a vacuum of approximately 0,6 bar The spindle (6) should be at rest, as "b".
Parts & tools for this job For 2001 Citroën C5
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit