Removing - Refitting: Coolant outlet housing (DW12C)
- Make
- Citroën
- Model
- C5 (X7) Factory Workshop Manual
- Year
- 2008–2017
- Section
- Cooling system › Removing - Refitting: Coolant outlet housing (DW12C)
Removing - Refitting: Coolant outlet housing (DW12C)
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Tooling
| tool | Reference | Designation |
|---|---|---|
| [0165-Z] | Pliers for spring collar |
2. Removing
Drain the cooling system.
Disconnect the battery.
Disconnect connector of the air flowmeter (at "a").
Remove: The air filter housing (1).
Loosen and release the clamps () (at "b"); Using tool [0165-Z].
Uncouple:
- The hoses (5)
- The pipe (3)
Remove:
- The mountings (4)
- The nuts (2)
Unplug: The connector of the coolant temperature sensor (7).
Remove the 2 studs (6).
Remove:
- The thermostat (8)
- The clip retaining the coolant temperature sensor (7) (as "c")
- The coolant temperature sensor (7)
3. Refitting
CAUTION: Adhere to the tightening torques.
CAUTION: It is imperative to replace: The gasket of the coolant outlet housing (8).
Refit:
- The coolant temperature sensor (7)
- The clip retaining the coolant temperature sensor (7) (as "c")
- The thermostat (8) (with its new seal)
- The 2 studs (6)
- The nuts (2)
- The mountings (4)
Tighten:
- The 2 studs (6)
- The nuts (2)
- The mountings (4)
Couple up:
- The pipe (3)
- The hoses (5)
Reposition: The clips (at "b"); Using tool [0165-Z].
Refit the air cleaner housing (1).
Reconnect connector of the air flow sensor (at "a").
Fill and bleed the cooling system.
CAUTION: Ensure there are no leaks from the circuit of the cooling system.
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Reconnect the battery.
Parts & tools for this job For 2008 Citroën C5
- FLUIDCoolantSearch: Citroën coolant antifreeze
- PARTThermostatSearch: Citroën C5 2008 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester
As an Amazon Associate we earn from qualifying purchases.